Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lab Chip ; 20(24): 4638-4639, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-33232426

RESUMO

Correction for 'A system for the high-throughput measurement of the shear modulus distribution of human red blood cells' by Amir Saadat et al., Lab Chip, 2020, 20, 2927-2936, DOI: 10.1039/D0LC00283F.

2.
Lab Chip ; 20(16): 2927-2936, 2020 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-32648561

RESUMO

Reduced deformability of red blood cells (RBCs) can affect the hemodynamics of the microcirculation and reduce oxygen transport efficiency. It is also well known that reduced RBC deformability is a signature of various physical disorders, including sepsis, and that the primary determinant of RBC deformability is the membrane shear modulus. To measure the distribution of an individual's RBC shear modulus with high throughput, we a) developed a high-fidelity computational model of RBCs in confined microchannels to inform design decisions; b) created a novel experimental system combining microfluidic flow, imaging, and image analysis; and c) performed automated comparisons between measured quantities and numerical predictions to extract quantitative measures of the RBC shear modulus for each of thousands of cells. We applied our computational simulation platform to construct the appropriate deformability figure(s) of merit to quantify RBC stiffness based on an experimentally measured, steady-state cell shape in flow through a microchannel. In particular, we determined a shape parameter based on the second moment of the cell shape that is sensitive to the changes in the membrane stiffness and cell size. We then conducted microfluidic experiments and developed custom automated image processing codes to identify and track the position and shape of individual RBCs within micro-constrictions. The fabricated microchannels include a square cross-section imaging region (7 by 7 µm) and we applied order 10 kPa pressure differences to induce order 10 mm s-1 cell velocities. The combination of modeling, microfluidics, and imaging enables, for the first time, quantitative measurement of the shear moduli of thousands of RBCs in human blood samples. We demonstrate the high-throughput features by sensitive quantification of the changes in the distribution of RBC stiffness with aging. This combined measurement and computational platform is ultimately intended to diagnose blood cell disorders in patients.


Assuntos
Deformação Eritrocítica , Eritrócitos , Forma Celular , Contagem de Eritrócitos , Humanos , Microfluídica
3.
BMC Pediatr ; 14: 106, 2014 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-24745348

RESUMO

BACKGROUND: Physical fitness has been proposed as a marker for health during adolescence. Currently, little is known about physical fitness and its association with blood lipid profile in adolescents from low and middle-income countries. The aim of this study is therefore to assess physical fitness among urban and rural adolescents and its associations with blood lipid profile in a middle-income country. METHODS: A cross-sectional study was conducted between January 2008 and April 2009 in 648 Ecuadorian adolescents (52.3% boys), aged 11 to 15 years, attending secondary schools in Cuenca (urban n = 490) and Nabón (rural n = 158). Data collection included anthropometric measures, application of the EUROFIT battery, dietary intake (2-day 24 h recall), socio-demographic characteristics, and blood samples from a subsample (n = 301). The FITNESGRAM standards were used to evaluate fitness. The associations of fitness and residential location with blood lipid profile were assessed by linear and logistic regression after adjusting for confounding factors. RESULTS: The majority (59%) of the adolescents exhibited low levels of aerobic capacity as defined by the FITNESSGRAM standards. Urban adolescents had significantly higher mean scores in five EUROFIT tests (20 m shuttle, speed shuttle run, plate tapping, sit-up and vertical jump) and significantly most favorable improved plasma lipid profile (triglycerides and HDL) as compared to rural adolescents. There was a weak association between blood lipid profile and physical fitness in both urban and rural adolescents, even after adjustment for confounding factors. CONCLUSIONS: Physical fitness, in our sample of Ecuadorian adolescents, was generally poor. Urban adolescents had better physical fitness and blood lipid profiles than rural adolescents. The differences in fitness did not explain those in blood lipid profile between urban and rural adolescents.


Assuntos
Lipídeos/sangue , Aptidão Física , Saúde da População Rural , Saúde da População Urbana , Adolescente , Criança , Estudos Transversais , Dieta , Equador , Exercício Físico , Feminino , Humanos , Masculino , Fatores Socioeconômicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...